Since R2 App-V is strongly integrated into SCCM.
A most common scenario will be that for instance a user logs on and the icon of avirtual application appears automatically on his desktop, ready to stream the application.
Default, you first get a notification (balloon in system tray) that the user has to click before the icon appears on its desktop.
That's probably something you don't want to have. You probably prefer if the user logs on the icon will be available without user interaction.
As you might know you can suppress notification with SCCM on programs of SCCM packages... BUT App-V Packages do not have programs, so we cannot select this option.
At this point some scripting will be required.
With following script you suppress notifications for App-V packages.
strSMSServer = "."
strPackageID = "XYZ00001"
strProgramName = "[Virtual application]"
Set objLocator = CreateObject("WbemScripting.SWbemLocator")
Set objSCCM = objLocator.ConnectServer(strSMSServer, "root\sms")
Set Providers = objSCCM.ExecQuery("SELECT * From SMS_ProviderLocation WHERE ProviderForLocalSite = true")
For Each Provider in Providers
If Provider.ProviderForLocalSite = True Then
Set objSCCM = objLocator.ConnectServer(Provider.Machine, "root\sms\site_" & Provider.SiteCode)
' strSMSSiteCode = Loc.Sitecode
End If
Next
Set objProgram = objSCCM.Get("SMS_Program.PackageID='" & strPackageID & "',ProgramName='" & strProgramName & "'")
ProgramFlags = objProgram.ProgramFlags
WScript.Echo "Flags for " & strPackageID & ":" & strProgramName & " currently set to " & ProgramFlags
WScript.Echo "Adding 0x00000400 (COUNTDOWN. The countdown dialog is not displayed)" ' see ConfigMgr SDK for details ("SMS_Program Server WMI Class")
ProgramFlags = ProgramFlags + 1024
WScript.Echo "Set flag to: " & ProgramFlags
objProgram.ProgramFlags = ProgramFlags
objProgram.Put_
Enjoy!
vrijdag 23 april 2010
woensdag 6 januari 2010
Conigurations in bootstrap.ini are not applying
I've seen recently a lot of posts on forums of people that are having issues with their bootstrap.ini.
In other words if they change something to the ini file it does not get applied.
Well for once an for all, as bootstrap.ini gets executed in a very early stage during WinPe it's required that you create a new WinPe Installation CD each time you added some changes to bootstrap.ini.
So -> Change bootstrap.ini = New WinPE Installation CD
In other words if they change something to the ini file it does not get applied.
Well for once an for all, as bootstrap.ini gets executed in a very early stage during WinPe it's required that you create a new WinPe Installation CD each time you added some changes to bootstrap.ini.
So -> Change bootstrap.ini = New WinPE Installation CD
maandag 28 september 2009
MDT Wait for correct IP Address
It can happen when executing an LTI deployment that you get an error that your Deployment Share is not available.
If you hit F8 to open a DOS box and you notice you don't have an IP address (yet).
I have a trick how you can extend a bit the time for MDT to acquire an IP address.
I saw this already with several customers if they had some latency on their network cause by DHCP, network components,...
What you have to do is the following:
You mount your current boot image with imagex. (/mountrw)
Go to startnet.cmd and edit
Once you open the file in notepad the only contents will be the command:
wpeinit
Change the file to contain the following:
wpeutil InitializeNetwork
ping localhost (You could ping the WDS server too)
wpeinit
Save you changes of the cmd file.
Unmount the image and save your changes of the image. (/unmount /commit)
Burn this updated image to a new Installation CD or publish this image back to your WDS.
Your network issue should be solved now.
If you hit F8 to open a DOS box and you notice you don't have an IP address (yet).
I have a trick how you can extend a bit the time for MDT to acquire an IP address.
I saw this already with several customers if they had some latency on their network cause by DHCP, network components,...
What you have to do is the following:
You mount your current boot image with imagex. (/mountrw)
Go to startnet.cmd and edit
Once you open the file in notepad the only contents will be the command:
wpeinit
Change the file to contain the following:
wpeutil InitializeNetwork
ping localhost (You could ping the WDS server too)
wpeinit
Save you changes of the cmd file.
Unmount the image and save your changes of the image. (/unmount /commit)
Burn this updated image to a new Installation CD or publish this image back to your WDS.
Your network issue should be solved now.
dinsdag 28 juli 2009
Dynamically install drivers with MDT 2010

MDT 2010 has some nice new features, one of them are Selection Profiles.
Like Michael describes on his blog Selection Profiles can be used for several things into MDT.
http://blogs.technet.com/mniehaus/archive/2009/07/12/mdt-2010-new-feature-18-selection-profiles.aspx
Another nice thing to use Selection Profiles for is to install drivers on a dynamic basis.
Create a driver folder structure into MDT. Then create a Selection Profile and call it like the respectively model names. You can read the model name out of WMI by executing:
CMD -> WMIC
CSProduct Get Name
In CustomSettings.ini you just add:
DriverSelectionProfile=%model%
OR
If you don't want to create a Selection Profile for each model you can create a rule that checks the dirver structure:
DriverGroups001=%Model%
(remark: if you build your Driver structure you need to call the folders like the WMI product name - cf. like we did with Selection Profiles)
vrijdag 17 juli 2009
MDT Database connections wit MDT 2010
If you encounter issues connecting to the MDT database, do the following for troubleshooting.
Put following files into one folder:
ztigather.xml
ztigather.wsf
customsettings.ini (where you specifiy the connection to the DB)
ztiutility.vbs
ZTIDataAcess.vbs
Execute following command from a host that needs to connect to the DB.
cscript ztigather.wsf /debug:true
Most common issues are SQL permission or Named Pipes that isn't enabled in SQL.
Put following files into one folder:
ztigather.xml
ztigather.wsf
customsettings.ini (where you specifiy the connection to the DB)
ztiutility.vbs
ZTIDataAcess.vbs
Execute following command from a host that needs to connect to the DB.
cscript ztigather.wsf /debug:true
Most common issues are SQL permission or Named Pipes that isn't enabled in SQL.
vrijdag 26 juni 2009
MDT 2010 Beta 2
Available at the Microsoft Connect site.
From now on you have everything to test Windows 7 Deployments via SCCM.
Don't forget to install SP2 (also beta) of SCCM as well!
Nico
From now on you have everything to test Windows 7 Deployments via SCCM.
Don't forget to install SP2 (also beta) of SCCM as well!
Nico
dinsdag 12 mei 2009
OSD wipes the disk instead of formatting
Hi,
Did you ever noticed that if you change the advertisment distribution setting of your task sequence to "Access content directly..." your disk gets wiped instead of formatted?
The reason because of this is that MDT sets by default an argument on the "Format and Parition Disk" Task.
That argument looks like "_SMSTSDownloadOnDemand equals TRUE", if you remove this also your disk will be formatted when accessing the DP directly instead of downloading the content from the DP.
If you access the contect direcly you decrease the installation time significantly.
Nico
Did you ever noticed that if you change the advertisment distribution setting of your task sequence to "Access content directly..." your disk gets wiped instead of formatted?
The reason because of this is that MDT sets by default an argument on the "Format and Parition Disk" Task.
That argument looks like "_SMSTSDownloadOnDemand equals TRUE", if you remove this also your disk will be formatted when accessing the DP directly instead of downloading the content from the DP.
If you access the contect direcly you decrease the installation time significantly.
Nico
Abonneren op:
Posts (Atom)